Audio Cable - Multipair Unshielded &
Shielded Groups
| 300V NS 30V |
60°C 80°C 80°C |
2094, CM 2717 2919 |
Detailed
description under each part number |
UL AWM Styles (As Noted) UL Listed Type CM (300V only) OSHA Acceptable CSA Certified CMG (FT-4)^ |
|||
![]() |
DESCRIPTION: | ||||||
|
|||||||
| PART NO. |
NO. OF COND. |
COND. SIZE |
NOM. INSUL. THICK. INCHES |
NOM. JKT. THICK. INCHES |
NOM. O.D. INCHES |
APPROX. WT./M LBS. |
COLOR CODE |
NOMINAL CAPACITANCE + |
SUGG. WKG. VOLT. |
UL STYLE NO. |
|
| PF/FT* | PF/FT** | ||||||||||
| M4451 | 4 {2 Shld. {2 Unshld. |
#22 (7/30) | .008 | .019 | .165 | 21 | Red, Blk Grn, Wht |
34 | 67 | 300 | CM |
| Paired
tinned copper, polypropylene insulated conductors. One
pair shielded with aluminum/polyester foil in continuous contact with a #24 AWG stranded tinned copper drain wire. One pair unshielded. Chrome gray PVC jacket. |
|||||||||||
| M4452^ | 4 {2 Shld. {2 Unshld. |
#20 (7/28) | .015 | .028 | .226 | 35 | Red, Blk Grn, Wht |
60 | 99 | 350 | - |
| Paired
tinned copper, PVC insulated conductors. One pair
shielded with aluminum/polyester foil in continuous contact with a #22 AWG stranded tinned copper drain wire. One pair unshielded. Chrome gray PVC jacket. |
|||||||||||
| M4473 | 4 {2 Pairs {2 Shld. |
#22 (7/30) | .010 | .019 | .168 | 22 | Red, Blk Grn, Wht |
35 | 62 | 300 | 2919 CM |
| Paired
tinned copper, polypropylene insulated conductors. Each
pair is individually shielded with aluminum/ polyester foil in continuous contact with a #24 AWG stranded tinned copper drain wire. To reduce O.D. pairs are cabled on common axis under a chrome gray PVC jacket. 100% shield coverage. |
|||||||||||
| M14474 | 4 {2 Pairs {2 Shld. |
#22 (7/30) | .010 | .028 | .215 | 30 | Red, Blk, Grn, Wht |
35 | 62 | 300 | 2717 CM |
| Paired
tinned copper, polypropylene insulated conductors. Each
pair is individually shielded with aluminum/ polyester foil in continuous contact with a #24 AWG stranded tinned copper drain wire. Polyester film over each pair. Overall aluminum/polyester foil under a chrome gray PVC jacket. 100% shield coverage. |
|||||||||||
| M4475^ | 3 {2 Shld. {1 Unshld. |
#22 (7/30) | .013 | .032 | .199 | 24 | Blk, Red Brn |
60 | 99 | 150 | - |
| (Pair Only) | |||||||||||
| Tinned
copper, PVC insulated conductors. One (1) pair
aluminum/polyester foil in continuous contact with #22 AWG stranded tinned copper drain wire cabled with one (1) conductor unshielded under a chrome gray PVC jacket. |
|||||||||||
| M14476 | 4 {2 Shld. (2 Unshld. |
#22 (7/30) | .008 | .030 | .205 | 24 | Red, Blk Grn, Wht |
34 | 67 | 200 | - |
| Paired
tinned copper, polypropylene insulated conductors. One
pair shielded with aluminum/polyester foil in continuous contact with a #24 AWG drain wire. One pair unshielded. Chrome gray PVC jacket. |
|||||||||||
| M14477^ | 6 {4 Shld. {2 Unshld. |
#24 (7/32) #22 (7/30) |
.015 | .028 | .236 | 34 | Blk, Grn Red, Yel. Blu, Wht |
- | - | 350 | - |
| Tinned
copper, PVC insulated conductors cabled under an
aluminum/polyester foil in continuous contact with a #22 AWG stranded tinned copper drain wire. 2 PVC conductors unshielded. All cabled under a chrome gray PVC jacket. |
|||||||||||
| M14478 | 10 {4
Shld. {4 Shld. {2 Unshld. |
#24 (7/32) #24 (7/32) #22 (7/30) |
.012 | .030 | .290 | 53 | Gry, Wht Blu, Grn. Brn, Red Yel, Org. Wht, Blu |
- | - | 350 | - |
| #24 AWG
tinned copper conductors are polyethylene insulated and
cabled in 2 quads. One (1) quad has a red shield, the other has a green shield. The shield is aluminum/polyester in continous contact with a #24 AWG stranded tinned copper drain wire. The two unshielded #22 AWG conductors are PVC insulated. Entire assembly is cabled under a overall chrome gray PVC jacket. |
|||||||||||
| M14475 | 3-Shielded | #22 (7/30) | .008 | .020 | .145 | 18 | Blk, Red Wht |
32 | 60 | 200 | - |
| Tinned
copper, polypropylene insulated conductors. Cabled under
an aluminum/polyester foil in continuous contact with a #22 stranded tinned copper drain wire. 100% shield coverage. Brown PVC jacket. |
|||||||||||
| M13291 | 4 {2 Shld. {2 Shld. |
#20 (7/28) #18 (16/30) |
.020 | .031 | .262 | 47 | Blk, Red Grn, Wht |
24 | 46 | 300 | 2094 CM |
| Tinned
copper, polyethylene insulated conductors cabled under an
aluminum/polyester foil in continuous contact with a #22 AWG stranded tinned copper drain wire. 100% shield coverage. Beige PVC jacket. |
|||||||||||
| + At one (1) KHz * Capacitance between conductors. ** Capacitance between one (1) conductor and balance of conductors connected to shield. |
| REV 3/98 |