Heyco Liquid Tight Straight-Thru Fittings
For Flexible Cords

US PATENT No. 5,405,172
Foreign Patents
Listed
under Underwriters' Laboratories File #E-51579
Recognized under the Components Program of
Underwriters' Laboratories File #E-51579
CSA Certified by Canadian Standards Association
File #LR-93876.
| |
|
Part |
No. |
|
A |
C |
D |
E |
F |
| Min. Dia. |
Max. Dia. |
Black |
Gray |
UL/CSA |
Clearance
Hole
in. mm. |
Max. O.A.
Length
in. mm. |
Thread Length
in. mm. |
Wrenching
Nut Thk.
in. mm. |
Wrenching
Flats
in. mm. |
| .064 1,6 |
.210 5,3 |
3444 |
3445 |
RLTF 7 |
.492 12,5 |
1.17 29,7 |
.33 8,4 |
.22 5,6 |
.59 15,0 |
| .114 2,9 |
.250 6,4 |
3207 |
3208 |
LTF 7 |
.492 12,5 |
1.17 29,7 |
.33
8,4 |
.22
5,6 |
.59 15,0 |
| .069 1,8 |
.187 4,7 |
3446 |
3447 |
RLTF 9 |
.599 15,2 |
1.30 33,0 |
.34 8,6 |
.20 5,1 |
.75 19,1 |
| .181 4,6 |
.312 7,9 |
3210 |
3211 |
LTF 9 |
.599 15,2 |
1.30 33,0 |
.34
8,6 |
.20
5,1 |
.75 19,1 |
| .069 1,8 |
.260 6,6 |
3448 |
3449 |
RLTF 11 |
.733 18,6 |
1.46 37,1 |
.39 9,9 |
.20 5,1 |
.86 19,1 |
| .230 5,8 |
.395 10,0 |
3213 |
3214 |
LTF 11 |
.733 18,6 |
1.46 37,1 |
.39
9,9 |
.20
5,1 |
.86 19,1 |
| .170 4,3 |
.470 11,9 |
3216 |
3217 |
LTF 13,5* |
.804 20,4 |
1.53 38,9 |
.41 10,4 |
.20 5,1 |
.95 24,1 |
| .230 5,8 |
.395 10,0 |
3219 |
3220 |
LTF 16* |
.886 22,5 |
1.66 42,2 |
.45 11,4 |
.23 5,8 |
1.05 26,7 |
| .250 6,4 |
.485 12,3 |
3454 |
3455 |
RLTF 21* |
1.115/28,3 |
1.87 47,5 |
.52 13,2 |
.23 5,8 |
1.30 33,0 |
| .450 11,4 |
.709 18,0 |
3222 |
3223 |
LTF 21 |
1.115/28,3 |
1.87 47,5 |
.52 13,2 |
.23 5,8 |
1.30 33,0 |
| .590 15,0 |
1.000 25,4 |
3225 |
3226 |
LTF 29* |
1.470/37,3 |
2.23 56,6 |
.59 15,0 |
.28 7,1 |
1.66 42,2 |
| .787 20,0 |
1.020 26,0 |
3206 |
- |
RLTF 36* |
1.85 47,0 |
2.38 60,5 |
.50 12,7 |
.32 8,1 |
2.09 53,1 |
| .866 22,0 |
1.260 32,0 |
3204 |
- |
LTF 36* |
1.85 47,0 |
2.38 60,5 |
.50 12,7 |
.32 8,1 |
2.09 53,1 |
| .984 25,0 |
1.220 31,0 |
3218 |
- |
RLTF 42* |
2.125/54,0 |
2.36 60,0 |
.51 13,0 |
.33 8,3 |
2.36 60,0 |
| 1.260 32,0 |
1.496 38,0 |
3212 |
- |
LTF 42* |
2.125/54,0 |
2.36 60,0 |
.51 13,0 |
.33 8,3 |
2.36 60,0 |
| 1.142 29,0 |
1.378 35,0 |
3283 |
- |
RLTF 48* |
2.335/59,3 |
2.40 60,0 |
.55 13,0 |
.33 8,3 |
2.56 65,0 |
| 1.457 37,0 |
1.732 44,0 |
3281 |
- |
LTF 48* |
2.335/59,3 |
2.40 61,0 |
.55 14,0 |
.33 8,3 |
2.56 65,0 |
Standard Color: Black, gray available at extra charge.
* Listed under Underwriters' Laboratories
- NEW! Acme threads on body prevent skipping, speed installation.
- "Pg" hub threads are steel conduit threads per DIN 40430. For DIN 40430
see page 1-20.
- Seventeen sizes for cable, tubing, etc. with diameters ranging from
.064"(1.6mm) to 1.732"(44,0mm).
- We recommend using the smallest maximum diameter Fitting that will fit your
application.
- All nylon construction with TPE gland resists salt water, weak acids, gasoline,
alcohol, oil,
grease and common solvents.
- Working temperatures:-22°F(-30°C) to 212°F(100°C). For short periods to
302°F(150°C).
- Protection class IP 68 per DIN 40050 up to 70 psi (5 bar) water pressure.
- Suitable for NEMA type 4 and 6 enclosures.
- Locknuts are included. for nylon locknut specifications or to order locknuts
separately see page 1-13.


|