| Run under Acrobat Reader. Press Download , if you still do
not have Acrobat Reader in your system. |
|
| MODEL |
Rated
Voltage |
Operating
Voltage Range |
Rated
Current |
Rated
Input Power |
Speed |
Maximum
Air Flow |
Maximum
Air Pressure |
Noise |
| 2
Balls |
Function |
VDC |
VDC |
Amp |
Watt |
R.P.M. |
m3/min |
CFM |
mmH2O |
IN
H2O |
dB-A |
| BFB0405LE |
-R00 /
-F00 |
5 |
4.0 to
5.5 |
0.06 |
0.30 |
3500 |
0.05 |
1.62 |
3.2 |
0.13 |
26.0 |
| BFB0412LE |
-R00 /
-F00 |
12 |
10.0 to
13.8 |
0.04 |
0.48 |
| BFB0405ME |
-R00 /
-F00 |
5 |
4.0 to
5.5 |
0.13 |
0.65 |
4500 |
0.06 |
2.08 |
5.9 |
0.23 |
30.0 |
| BFB0412ME |
-R00 /
-F00 |
12 |
10.0 to
13.8 |
0.05 |
0.60 |
| BFB0405HE |
-R00 /
-F00 |
5 |
4.0 to
5.5 |
0.22 |
1.10 |
5500 |
0.07 |
2.54 |
9.7 |
0.38 |
35.5 |
| BFB0412HE |
-R00 /
-F00 |
12 |
10.0 to
13.8 |
0.07 |
0.84 |
| BFB0412HHE |
-R00 /
-F00 |
12 |
10.0 to
13.8 |
0.11 |
1.32 |
6500 |
0.08 |
2.97 |
14.2 |
0.56 |
39.5 |
| |
|
|
|
|